Prusa mini pinda probe height

Fox Business Outlook: Costco using some of its savings from GOP tax reform bill to raise their minimum wage to $14 an hour. 

I'm considering swapping out the Bltouch on my CR-10 with an inductive probe. Very reliable and consistent, but top surfaces are slightly rough where retractions occured and later changes show artifacts. 5S, MK3, and MK3S. If you're close to or above -2, you need to reposition the PINDA higher. Consistent Z height would streamline the printing experience a lot. That @#^$% clampit has just enough resistance that you can't gently dial in the height of the probe ("Just a little harderjust a bit morejust a <THUMP> DAMMIT!") & just enough fragility to break The company was founded by Josef Prusa, one of the core members of the open-source RepRap community, in 2012. Do not pull out the connector without pressing the pin, it may damage the connector or the board. 8mm adjustment . I don’t like paying $60 postage for a $10 part. . 30 mm (can't recall where). Show off your prints, or ask a question… Product Details. carefully 3, readjust the live Z to the new Pinda Position again for best results. I don’t remember seeing people asking for a brand new SuperPINDA at almost double the price of the PINDA2! Jun 3, 2021 · For a Mk3 or mini Zero is the point where the pinda detects the bed. In my experience, the first layer Z height is higher if printing from cold, and lower (ie. Curious if yours is close. Use one of your zip ties as a height gauge for the PINDA. For a printer with a physical switch its the point at which the switch gets activated. Just put the probe in the thing, push it down so it sits on the shoulder, & zip tie that little bastard down. Do not place the firmware on a network share. ⬢ Guide the print fan cable through MINI-fan-spacer-clip groove. Step 10 Removing the M. Installing the SuperPINDA Probe Upgrade on my Prusa Mini. Tento návod se zabývá nastavením senzoru M. By rotating the rod. Sep 6, 2018 · 1) First, I had set the PINDA probe at zip-tie height above the nozzle, as described in section 9 of the online assembly manual. 0mm per turn so this should reduce the gap between the nozzle and the build plate by one millimetre. 0. So a -1000 is basically moving the nozzle 1mm closer to the bed surface. I have seen recommendations for PINDA Lift as low as 0. If it does not change from 0 to 1, push the FINDA down a little bit. I can give a clearer example regarding it "Not holding an offset": I did this process several times over the past few days. 1x Some kind of Pinda probe. Several retries led to the same outcome. After changing the height of the PINDA probe, I do a hard reset and go through the calibration sequence (Factory Reset, Reflash 3. Note, the Prusa Mini uses a Minda instead of the Pinda in the Mk2 or Mk3, but the adjustment process is similar Sep 3, 2021 · so first of all re adjust Live Z back towards 0. 5/S, Mini + 3D Printer Visit the POLISI3D Store 2. Its the speed at which the movement command is performed at. /SuperPINDA sensor height is set during the production. I believe that’s for troubleshooting the probe, not determining which probe you have. After OK checks for X and Y movement, the nozzle just crashes into the heatbed and I have to abort. Download a first layer calibration shape (circle, square, whatever) from popular STL sites and make sure your print lines are touching. The Zelda shows the vertical fine artifacts caused by having an extremely rigid frame (I have a prusa i3 mk3s bear modded printer, so the frame is extremely PINDA Probe V1. I'm like Jon Snow, I know nothing. Then redo your calibration. Než nahradíte starší sondu senzorem SuperPINDA, ujistěte se, že používáte verzi firmwaru 3. Tighten the screw again. 5/S and MK3/S/+. The SPA allows precise adjustment of the height of the SuperPINDA probe via rotation of the SPA. Includes: SuperPINDA (1 pcs) Fits: MK2. Place a zip tie flat on the bed and lower the PINDA down onto it, and then tighten the screw back up again. 101 6 days ago · Explore Category. hex). 5 / Mini. Add a comment. The most tedious part of the installation is the re-installation of the cable wrap. Orient the clip as shown in the picture, the beveled side is up. ⬢ Open PrusaSlicer and select Configuration ->Flash Printer Firmware from the top menu. ⬢ Carefully lower down the entire X-axis by rotating the lead screw. Download. The status on the menu should turn to 1, and the light on top of the sensor should go OFF. (MINI). prusa3d. As far as washing the steel plate goes, I typically wash the plate every 4-5 prints and just do an IPA wipe in between. Hi Peter, I'm not sure yet what is the "official" distance, but in my case it looks like around 1 mm. From the front panel select: “Info” Select “Sensor Info” There is a line that says M. You could raise z watch the light and move metal to the tip of the pinda. ⬢ Now, take the M3nE nut in the upper part of the extrusion and slide it under the steel plate. Jan 27, 2019 · MK3 Nozzle to PINDA Height Distance. It looks like the M851 gcode can be used to specify a custom XYZ offset, but the Prusa docs say it only accepts Z-offsets (not XY). I recently built a custom X-axis extruder mount for the Revo Hemera XS, but auto-bed leveling is failing because the PINDA probe runs off the edge of the bed during calibration. adjustment (part 1) Ensure the printer is turned off and not plugged in. The SuperPINDA Precision Adjuster is a two-part design, the SPA and a required modification to the MK3S+ extruder body. 1920 "prusa mini pinda" 3D Models. Every Day new 3D Models from all over the World. You'll notice that the first 1. Sep 25, 2019 · When I set it to the standard height of a prusa PINDA, it detects the steel sheet correctly for mesh bed leveling. But Prusa decided that the MK2 (S) users are not worthy of such fix, so the've embarked 15 votes, 17 comments. Jul 3, 2018 · The pinda has a light that triggers when you put it close to metal. Step 1 P. 5S MK3 MK3S MK3S+ Mini Mini+. Like some club card, which has no magnetic/electronics inside due to magnets (usually have 1,3mm height) Lower (rotate) by hand the X rolley (Z height) down, until hotend touch cold bed. Keep in mind : Always recalibrate the Z-live after a P. A of your Prusa Mk3S / Mk3 / Mk2. ⬢ Slide the sleeve in the holder on the Einsy base at least 3/4 of the holder's height. If it does not I would consider your pinda broken. 0 from the bed instead of closer to zero or - 2 so there's room to play and make sure the sensor is properly adjusted. It doesn't trigger on just the prusa calibration points in the bed, but seems to trigger everywhwere on the PCB, so prusa standard XYZ calibration can't Jan 29, 2022 · RE: Two questions about PINDA and Super PINDA probes. Mar 21, 2020 · RE: Brand new prusa mini: Z needs to adjust on every new print. 2mm layer height being printed, but actual results can vary. I've just finished the kit and I can't get the PINDA sensor to move for adjustment. At first I was way higher and the PINDA didn't probe well, having often the extruder pressing the heatbed during calibration. A Step 10 Guiding the cable bundle. The Z=0 position detected by the PINDA probe may be sub-optimal for a number of reasons: We want a bit more or less squish with some filaments for better bed adhesion. Kind of a bummer if I have to move the Pinda Krok 1 Úvod. My left hand is partially dis-abled . Print instructions. Everything smaller is too small to matter. Use the Allen key to align it. If you've seen my channel then you'd know that this P. Once because I changed to a longer nozzle and didnt realise I had to re-set the PINDA probe height to compensate for the difference in nozzle size. Verify that the printer is turned on. Prusa INDuction Autoleveling probe, is a vital component facilitating the calibration of our printers. Step 8 Updating both firmwares using PrusaSlicer. The SuperPINDA offers enhanced sensitivity Step 16 Joining the parts together - phase 3. I certainly don’t like the fact that my open source printer is not quite open source. 0 mm. The difference is that the V2 has an inbuilt thermistor to compensate for the difference in cold and hot measurements. SuperPINDA nahrazuje původní sondy P. BOM. Yes i know this is also the thickness or a simple calbe-tie! But i ran out of those so this little print came to the rescue. NEMA17 Mini Belt Driven; Shop All Mar 4, 2017 · First time it has ever done that. 59K subscribers in the prusa3d community. Don't get anal about the numbers of a z-offset, they're semi-arbitrary. 78 votes, 17 comments. People assembling the Kit version of the Mini+ don't have issues with the Pinda height because you adjust this during installation. Making the first layer calibration and. Pokud máte MK2/S, najdete tam hodnotu Z. sensor. 3 a novější (pokud nejde o model MK2/S), jděte do LCD menu -> Podpora -> Senzor info a zjistěte hodnotu sondy ( 'PINDA:' 1 nebo 0) U firmwaru staršího než verze 3. Apr 16, 2018 · PINDA Probe problem. @eirlink. Place a metal object below the M. má žlutou špičku, zatímco senzor SuperPINDA má černou špičku. 8mm). The bad: It seems like it's more sensitive compared to the original PINDA. Postup pro jeho nastavení je u obou verzí stejný. Making the first layer calibration and The company was founded by Josef Prusa, one of the core members of the open-source RepRap community, in 2012. Compatible with Mk3S, Mk3, Mk2. Aug 4, 2020 · RE: Pinda probe height simple question. Feb 16, 2021 · Tool to adjust height of Super PINDA (SPINDA) sensor on Mk3S and Mini | Download free 3D printable STL models Pinda and Minda probe height adjustment tool . 3 se hodnota P. SuperPINDA má vysoce kvalitní senzor, její funkce je nezávislá na teplotě a nepotřebuje termistor. I'll definitely give the MINDA probe height and the PTFE issue a closer look during my installation. You have to move the frame slightly away from you at the threaded rods. spin. 9 out of 5 stars 6 ratings Step 11 Flash Bear firmware for calibration. If it fails to trigger then you went too high. Avoid cutting the cables! ⬢ Release two screws on the cable clip and remove the clip. When replacing the original probe with SuperPINDA make sure to use the 3. The pictures besides the blue Zelda come from the Prusa Mini. I go over some reasons as to I feel like inductive probes don't get the support they deserve. I meant loosen the screw holding the Pinda (Minda?) probe and pull it up a bit, like 1 or 2 threads, then re-home the machine. SuperPINDA is temperature-independent, with higher quality sensor, and doesn't need a thermistor. Jan 19, 2020 · 2. Installation was straight forward. ssenzoru nachází v LCD menu -> Kalibrace -> Stav konc. Jan 8, 2019 · Loosen PINDA securing bolt. Prusa Mini owner since August '20. ⬢ Correct height between nozzle's tip and the sensor is 0. My design has physical threads that match the threads on the probe 43 votes, 16 comments. This usually doesn’t matter. ABS: bed 100°C, nozzle 250°C. It serves as a high-precision sensor that accurately measures the distance between the print nozzle and the print bed. Bltouch firmware comes pre-built for every board and printer brand. In this video I install the Prusa Mini SuperPINDA upgrade kit for my Prusa Mini that unfortunately had the terrible MINDA probe. 2 nebo vyšší. Click to find the best Results for prusa mini pinda Models for your 3D Printer. But my printer wouldn't pass the 4 point xyz calibration test. Show off your prints, or ask a question… Feb 15, 2021 · the difference in height between the Nozzle and the minda should be adjustable during assemble, but relatively 'fixed' durig use. more squishing) if printing from hot. With FW 3. Adjust your pinda probe, a good starting point is to manually move the print head down until the nozzle touches the bed, then place a zip tie under the pinda probe to adjust its position. Jul 6, 2016 · Re: PINDA Probe height in relation to extruder nozzle. 5/S) and M. You can check its proper position by following this step. The thickness of the thinner portion is the height you will set your PINDA above the paper. V2 (MK3/S, MK2. Interesting. 調整方法はどちらのバージョンも同じです。. Log in to be able to post. The FINDA value should turn from 0 to 1 . This will give you some more room to calibrate your Z. Click & Print preview. Move with the extruder reasonably slowly and in the future always use the printer's controls. While the metal object is below the M. The manual says to set the PINDA probe height with the middle of a ZIP tie provided this did not work. Senzor M. 9. 5. D. It seems to me that it should be close enough to proceed. 25 mm nozzle. Insert any 1. 00mm then loosen your pinda probe clamp and move the Pinda UP, one click (One thread) the Pitch of the Pinda thread is 1. 2mm 1st layer height in your slicer will result in a 0. Make sure to follow the manual for your printer model. Compatible printer models: MK3/S/+, MK2. is ON. ⬢ Make sure the hole in the nut matches the hole in the plate. The point of all this is to get you some more clearance between the probe and the bed in turn giving you more z height adjustment. Aug 26, 2021 · Adjusting the height of the PINDA sensor. Verify that the printer is detected in the "Serial port:" window. Jul 26, 2017 · Prusa will sell you a new PINDA and at a very reasonable price, about $10 but it’s not listed. Open the LCD menu -> Support -> Sensor info and focus on the FINDA value. 0=No 1=Yes. TPU: bed 60°C, nozzle 210°C. hex file using the Browse button. ⬢ Make sure the printer is turned on. sensor from the board. All the PINDA probe protectors i have found, including the one Prusa made, were just not good enough for me. Sure they work with multiple surface types, but you can get inductive probes at 1/3 the cost. Since 2012, more than 150. Dec 7, 2017 · I followed the manual and used a zip tie for height. 2 In order to make the PINDA probe work at all I had the set the probe height to just 3 layers of paper. Just a simple tool to set the correct height of the Pinda or Minda probe. センサーとSuperPINDAセンサーの調整について 説明します。. Some people will have a good z-offset at 0. at this stage the Z height will be reported as 0. ⬢ Use the Extruder-cable-clip and two M3x10 screws to fix the cable bundle in place. A. With the advent of interchangeable build plates and different build plate surface materials, it is useful to have a bit extra LiveZ Apr 30, 2021 · RE: Mini Plus Review and fixes from engineer's POV. ONLY compatible with the MK2 and MK2S. ok, looking at your pictures, you seem to have two issues: 1) The position of the Z frame along the Y threaded rods is not correct. The aim is to adjust the nozzle height until the extruded plastic sticks nicely to the bed and you can see that it is being slightly squished. 5, Mini with stock PINDA Note: When replacing the original probe with SuperPINDA make sure to use the 3. Replacement Prusa PINDA Probe V2, 750mm cable with Molex connector ready to plug into the Einsy Rambo. 75 mm filament into the selector. On mine it was way too high so the nozzle was hitting the bed before the bed was detected by the probe. The Super PINDA should have about 1. 5 MK2. Hello makers! I made a SuperPINDA calibration JIG to help me and others to calibrate the probe height everytime we need in a… Apr 15, 2018 · Also, the thickness of the steel sheet may come into play - the BuildTak FlexPlate is significantly thinner than the Prusa SSS - possibly causing PINDA sensing issues because the there is less "metal meat" to sense. As it happens, the level of it is about . 17 mm higher than dead flat on a cable tie. 1! (Mosquito will come someday if I get this working). Ensure the nylon filament isn't pushing the motor cables and if needed slightly unwrap the sleeve and push the filament up. Buy an Original Prusa SuperPINDA in Canada for 3D printers at low prices online. Includes: PINDA probe V1 (1 pcs) Fits: MK2 MK2S. The only idea I have is that I've heard that the PINDA probe loses accuracy when the temperature gets too high. But now when it is 2 days old, during Z Calibration the hotend is hitting the b Nov 24, 2020 · The only grief I have is with you Prusa guys screwing existing MK3S users by discontinuing a perfectly working PINDA2 probe. The Mini will be my first Prusa printer alongside my Ender 3 Pro. I. Do not remove the screw, you just need to be able to move the FINDA up and down. So I put the new Revo Six micro on my Prusa Mini. The First Layer Calibration is used to calibrate the distance between the tip of the nozzle and the print surface. At first the Z calibration went fine. 5/S, MINI/+. 5 will contain a PINDA probe with a thermistor inside, which can be used to compensate the PINDA probe in temperature, thus giving the user a consistent Z height. Unlike the P. Untight the pinda to be loose. My problem is that both the nozzle and PINDA probe have moved 17mm forward and 0. All that the Mini users, including myself, wanted was to have the PINDA2 work on the Mini. V2, the SuperPINDA does not have a thermistor, but due to its high-quality components, a thermistor is not necessary. That why the 'live z' value is negative. 2 or higher firmware version. Nov 30, 2019 · this means that the distance between the nozzle which is fixed to move up and down in relation to the Pinda, will be a safe distance above the build plate, but because of the initial set up, the Nozzle tip will be closer to the build plate than the pinda tip. Then tried swapping to the smaller 0. Wondering if I need to adjust the Pinda probe to be lower. The Filament sensor is also on the same menu. /SuperPINDA sensor height. F is feed rate. A adjustment. Mesh bed leveling a kalibrace první vrstvy jsou tím pádem daleko jednodušší Nope. Why won't Prusa fix the PINDA probe on the MK2 (S) ? The new MK3 and the new MK2. And when doing a first layer test, I noticed that the layer should still be a bit more squashed, but I can't change the z-offset past -2. Sep 21, 2016 · Re: Bent PINDA mount. A modified dragon toolhead cowling to mount a pinda (or superpinda, or vinda) probe to your V0. 65K subscribers in the prusa3d community. 1. No support needed. 10, Self Test, XYZ, Z). There are 2 different versions: V1, used in MK2/S, and V2, used on MK2. N. Personally, I would pay more for a temperature compensated probe. the minda estimates a distance between it's tip and the build plate and then live Z adjusts the nozzle closer to the build plate, from the position the Minda sensed. センサーは黄色、SuperPINDAセンサーは黒色です。. Přidat komentář. Loosen the screw that holds the PINDA probe and place a credit card under it and push the probe against the card. 9 2. Step 2 Adjusting M. I designed this to replace the stock MK3 "Extruder Body" part, robustly securing the probe at the correct right height off the print bed & locking it in place with the small zip ties that come with MK3. ⬢ Open the Einsy case and cut the two zip ties on the cable bundle. /SuperPINDA. 5S / Mk2. 2) From the pictures it seems that it is not the PINDA probe that is not perpendicular, but the whole X axis is skewed. Put below the PINDA something like a credit card. 9 1 Add to Collection. As between PINDA and bed is the card, I tight the PINDA. Nov 3, 2018 · Fix MK2 PINDA. The SuperPINDA Precision Adjuster also provides a much more secure mount for the SuperPINDA probe when the clamping screw is I purchased this Prusa i3 MK2 assembled. D height calibration tool will be invaluable to fine tune the height of the P. Making the first layer calibration and mesh bed Sep 25, 2019 · MK3s+ SuperPINDA Probe 5V 3PIN Super PINDA Auto Bed Leveling Sensor Compatible with Prusa i3 MK3/S/+, MK2. The Prusa team just recently released the SuperPINDA Probe upgrade for the Prusa Mini as well as th SuperPINDA replaces the P. 05 until the final adjustment where you go that small. Making the first layer calibration and mesh bed Jun 2, 2021 · The Prusa i3 MK3 is a remarkable machine, a triumph of trial-and-error, engineering, & design. All things related to Prusa 3D printers. I definitely understand that if the PINDA is too high the nozzle would crash before the PINDA signaled to stop, but if the nozzle was pushing that far down wouldn't the PINDA then be close enough to signal the stop? Aug 9, 2021 · Ideally, setting a 0. value is 0, and the red light coming out on top of the M. 000 Original Prusa 3D printers has been sold worldwide, receiving praise from both the media and 3D printing enthusiasts. It should go off in the range of 2mm. Ok, I found it in the firmware. That's the thickness of two sheets of paper. The other time it happened, I dont know why it was but i've had bed levelling problems ever since. 5 or so is thinner than the rest of the zip tie. 125, others at 1. Shoot for closer to - 1. Looking for something that's about 8mm diameter. このガイドは、 Original Prusa MINI and MINI+のM. I saw another comment on here about temperature affecting the probe. 8mm height adjustment tool to easy calibrate your P. In Z Calibration, am I supposed to only use the heat bed? Will it be OK to have a piece of paper on top of the bed to avoid scratching? Use paper as in the video. 8-1. P. Jan 31, 2022 · In this video we have explained how to set PINDA probe at a correct height so that it doesn't give the error of "BED LEVELLING FAILED, SENSOR DID'NT TRIGGER" SuperPINDA. 0 mm BUT the nozzle will always be Step 4 Disconnecting the SuperPINDA sensor. 5mm to the right. ⬢ Fix both parts together using the M3x12 screw, tighten it slightly. Prusa Research develops and produces 3D printers exclusively in its Prague's HQ. The directions on the Prusa web site are spot on. 5, MK2. Loosen the PINDA probe screw and pull the PINDA up a little. Select the appropriate Bear calibration firmware *. The M. I noticed with the new extruder design that comes with the mk2s, the probe PINDA 0. 2) I lowered the PINDA probe a bit, to about six sheets of paper above the Mini Afterburner Pinda Probe Mount. com/en/guide/how-to-change-a-m-i-n-d-a-sensor-mini_115145 Pokud máte firmware verze 3. Are you sure the PINDA probe broke? When you change a nozzle it's expected that your z-offset is going to change, it's part of the process. ⬢ Slide down the MINI-fan-spacer-clip and mount it on the spacer with the M3x20 screw. I've had this happen to me twice now. Do a new PID calibration. 2 mm layer heights or the reference surface is not perfectly at 1 mm thickness. sensor (old design) Press the safety pin on the connector and disconnect the M. I took the liberty of borrowing a few of the design elements of Prusas protector over to my design. Asking for official info from PRUSA Support. While moving with the extruder, the X-axis motor works as a generator. PINDA stands for Prusa INDuction Autoleveling probe, which is a vital component facilitating automatic calibration. It is NOT compatible with MK2. Loosen the Pinda clamp, raise the Pinda a touch, re tighten the Pinda Clamp. The Original Prusa SuperPINDA is an upgraded version of the PINDA probe, specifically designed for the Original Prusa 3D printers. It is an inductive probe compatible with our FFF printers. ⬢ Disconnect the SuperPINDA sensor cable from the EINSY board. Doing some research, I found the show endstop setting and used that to check the probe. As a result when I try and calibrate the printer it moves to the home position and the PINDA probe is too far out over the heatbed so it doesn May 1, 2020 · https://help. I was starting a print and the printer was doing the mesh leveling, but on the second point, the printer reported the probe did not trigger. (For the old PINDA, it was 0. Mar 16, 2021 · Wrong PINDA height. You will create a small amount of electricity and the LCD might flicker. 5S, Mk2. tighten the Pinda clamp and re run Live 'Z' adjustment". While I spent a lot of time tinkering with my Ender 3, I won't shy away from tinkering with the Mini as long as I can avoid any critical problems from the get-go. com/en/https://help. Making the first layer calibration Jul 19, 2018 · Also, the first time the extruder crashed into the bed it pushed the bed down probably a centimeter before the power down stopped it. As part of a project with my university, I have developed a new extruder to attach to a Prusa i3 MK2. 0. ⬢ First, select the printer's firmware file on your harddrive (. My Superpinda experience. To replace this part, please consult the Prusa Assembly Manuals. Whilst -1mm to -2mm is now considered acceptable I would try to get a smaller number because it gives you greater clearance for the PINDA, in the event of the model warping. If you get mesh bed leveling errors saying it can't finish then double check the height of the PINDA probe. Once PINDA is at correct height, re-tighten PINDA securing bolt. 5/S) a M. Only 10 minutes to print. You have to ask one of their sales agents and then you have to pay postage, lots of postage, $60 in my case. Don't go in steps smaller than 0. I then moved the probe a whole turn down and the calibration passed, but I had to adjust the live-Z setting to about -900 / -1000, which sounds like a lot. The printers assembled in the Prusa factory are already fine-tuned and this calibration Feb 21, 2018 · 5. 8mm Body Diameter, 5V DC. I was lucky and snagged a Mini+ upgrade, which I received a couple of days ago. If you're getting close to or above -2, I would reposition the PINDA higher. It does change from a 0 to a 1, but I have to put the metal source almost right on the probe. Distorted bed (often bed fixings too tight, especially if you have the 'U' bolt type) Bad calibration point (contact Prusa) 1. Description. PINDA placement on new Prusa MINI. Step 14 Guiding the textile sleeve. ⬢ Push all the cables from the print head into the MINI-fan-spacer-clip. Just print at 0. 5 mm distance between nozzle and SPINDA, so that you’re around -1 when your Live Z is correct. Start PrusaSlicer and navigate to the top menu Configuration -> Flash print firmware. if you have to move the nozzle too far, to get a Jul 3, 2018 · Correct PINDA Probe height setting or bad PINDA probe? The manual says to set the PINDA probe height with the middle of a ZIP tie provided this did not work. The single part of the thing that makes me burn with an incomprehensible rage is the PINDA mount. Setting the PINDA probe to the correct height is covered in the assembly of other Prusa printers In the printer's menu, go to Info -> Sensor Info, and see if the M. That might explain the problem with the ABS where the bed is 100°C, but for the TPU at only 60°C that's Lower your nozzle until it is almost touching the bed. SuperPINDA replaces the P. ⬢ Release slightly the screw on the minda-clip. a SuperPINDA na tiskárně Original Prusa MINI a MINI+. Here are the settings I'm using: PLA: bed 45°C, nozzle 215°C. th xn wh wc kl be dt cn bs wz